06 — ECG signal processing

flowchart LR
    RAW["raw recording\ndrifty, unaligned"] --> BASE["median filter\nsubtract slow drift"]
    BASE --> WIN["R-peak windowing\ncut aligned windows"]
    WIN --> NORM["z-score normalize\nkill volume differences"]
    NORM --> CLEAN["clean fixed-size beats"]
Step Problem Fix Concrete value
Sampling continuous voltage, model needs numbers store 360 numbers/s 0.6 s window ≈ 216 numbers
Baseline wander breathing drifts the trace up/down median filter tracks and subtracts drift keeps sharp QRS
Windowing beats start anywhere center every window on its R peak same alignment always
Normalization loud vs quiet recordings subtract mean, divide by spread shapes, not volume

Out: clean, aligned, same-size beat windows — the input to everything downstream.